Air Conditioning Installation - Brockton Capital

Brockton capital LLP
Level 1
89 Wardour Street
London
W1F 0UB

Brockton Capital was formed in 2005

The company invests in direct property, operating businesses that are heavily asset backed and property-related capital market securities.

Project Management

SR Builders- Bespoke building Contractors- Design Fit out

Emulsion Architecture- Bakers Yard London

MJD Air Conditioning Services Ltd- Mechanical Design & Installation

Tonhout crane Hire Ltd Welwyn Garden City

Air Conditioning & Heating

We have previously fully air conditioned Level 1 using a Daikin three pipe VRF system, which is still fully functional and maintained on regular service intervals by MJD. Our latest project for Brockton Capital was totally designed by MJD Air Conditioning Services Ltd. Eventually it was agreed that a Mitsubishi City Multi 2 pipe system would be installed on level 2 to provide Cooling , Heating, and hot water. The need for energy efficiency was paramount in the design stages to meet current regulations and legislations. The system was designed with the Enhanced Capital Allowance Scheme (ECA) so that Brocton Capital would benefit from utmost efficiency both financially and environmentally. Visit www.eca.gov.uk for further information. The external condensing unit was lifted to the roof early on Sunday 27th February 20111 by Tonhout Crane Hire Ltd, with a partial road closure. The unit was craned to the sixth floor roof top and positioned on the required condenser base. All of the existing systems serving level 2 were removed for recycling at Ampthill Metal Company

All areas were served by concealed chassis units enclosed in bespoke panelling and the air distribution to each area was provided via bronze linear grilles. All of the meeting rooms were fitted with wall mounted temperature sensors for optimum temperature control. A lossnay heat exchanger was installed to provide conditioned fresh air to all areas and extract air to keep the quality of air as pure as possible within all of the meeting rooms, reception area and the library. The lossnay unit will save around 30% on initial capital costs of the heating and cooling plant by reducing the load of the occupied space. The system is capable of utilising free cooling by using the outside temperature to help achieve the required temperature by free cooling or heat recovery.

Hot Water

A VRF Heat Pump Boiler was connected to the City Multi system. Hot water was provided for the kitchen area, sanitary areas including the shower room. The heat pump hot water boiler is far more efficient than a conventional gas boiler and will reclaim any heat dispersed when the main system is running in the cooling mode, providing free or cheap hot water.